*v 0008 *n code=0001 name="Supervisor" ^ nnReading configuration overrides from Data/persisted.cfg*n code=003C name="SBIT" =& n"git: 2020-01-24-A=& n0Kernel Release: 2.6.27.8*e code=0006 elementURI="depth" type=04 *a code=0407 owner=3FFF element=0006 universal=0006 unitName="meter" type=0B size=0003 fl=05  nl>*e code=0454 elementURI="DDM.cablePresent" type=02 *a code=0403 owner=3FFF element=0454 universal=3FFF unitName="bool" type=02 size=0001 fl=05 iL n=-{ n*Beginning Startup BIT*n code=003E name="CBIT" =K{ n6Beginning ground fault scan=u nuNo ground fault detected mA: CHAN A0 (Batt): -0.008853 CHAN A1 (24V): -0.027949 CHAN A2 (12V): -0.007309 CHAN A3 (5V): -0.002386 CHAN B0 (3.3V): -0.000004 CHAN B1 (3.15aV): -0.000337 CHAN B2 (3.15bV): 0.000021 CHAN B3 (GND): 0.001813 OPEN: 0.008214 Full Scale Calc: 4.765 mA, -1.589 mA*e code=0017 elementURI="latitude" type=04 *a code=05C7 owner=3FFF element=0017 universal=0017 unitName="degree" type=37 size=0006 fl=05 nO?*e code=001A elementURI="longitude" type=04 *a code=05C8 owner=3FFF element=001A universal=001A unitName="degree" type=37 size=0006 fl=05  n,R=P nSBIT PASSED=P nnListing configuration overrides from Data/persisted.cfg=P nVDUSBL_Hydroid.detectionThreshold=50 count; =P nBDropWeight.loadAtStartup=0 bool; =P nzExpress linearApproximation DDM.cablePresent 0.500000 count; =P nExpress linearApproximation acoustic_contact_range 10.000000 meter; =P nlVerticalControl.buoyancyNeutral=105 cubic_centimeter; =P nXVerticalControl.massDefault=0.5 centimeter; *n code=0043 name="MissionManager" !nR n.Started mission Startup\ n&>Z nO?Z nR