*v 0008 !Completed estimation for commanded vars: speed 1.00 m/s, pitch 20.00 deg, mass-position 4.48 mm. Average elevator angle=-0.927247 +/- 0.096953 deg (conf. level 99.90%, sigma: 0.350777 deg).=#E6Beginning ground fault scan=#UGround fault detected mA: CHAN A0 (Batt): 0.212770 CHAN A1 (24V): 0.326645 CHAN A2 (12V): 0.154660 CHAN A3 (5V): 0.044947 CHAN B0 (3.3V): 0.023371 CHAN B1 (3.15aV): 0.021242 CHAN B2 (3.15bV): 0.021684 CHAN B3 (GND): -0.067576 OPEN: 0.007280 Full Scale Calc: 4.765 mA, -1.589 mA]`Elevator uart error - getPosition.serial timeout=O Front detected. Continue flight for 1440.000000 seconds on heading 180.000000 degrees.=OJ$Continued flight (after front detection) completed. searchHdgSetting_ switches from 180.000000 degrees to 45.000000 degrees.U5HInvalid EZ Servo response:"/0@5242"=ahSBD MO Status=0, MOMSN=20144, MT Status=1, MTMSN=766=N aDgot command ! echo 1 > /dev/loadC1