*v 0008 IULCB fault: Invalid Command. Hardware Overcurrent Shutdown. Current Limiter Activated.&U6Beginning ground fault scan&-UGround fault detected mA: CHAN A0 (Batt): 0.506819 CHAN A1 (24V): 0.694149 CHAN A2 (12V): 0.167729 CHAN A3 (5V): -0.001180 CHAN B0 (3.3V): 0.000623 CHAN B1 (3.15aV): 0.000770 CHAN B2 (3.15bV): 0.000820 CHAN B3 (GND): -0.000225 OPEN: 0.006436 Full Scale: +/- 1 mAɠU:Expecting PD13 message formatwz̷UIThe patch peak is found before the maximum leg distance is reached. The patch peak is 0.483221 kg/m3 at 41.574687 arcdeg , -70.728791 arcdeg , distance = 1226.378669 m . Will continue flight for 30.000000 min .=ѿvU8Bearing = 150.000000 arcdeg