*v 0008 *n code=0001 name="Supervisor" ^nReading configuration overrides from Data/persisted.cfg*n code=0046 name="SBIT" =#\git: 2022-08-25=#\0Kernel Release: 2.6.27.8*n code=002F name="RDI_Pathfinder" [:Expecting PD13 message format*n code=0039 name="RudderServo" 6Rudder failed to initialize=#qz*Beginning Startup BIT*n code=0048 name="CBIT" =$uz6Beginning ground fault scan=$Ground fault detected mA: CHAN A0 (Batt): 0.767011 CHAN A1 (24V): 0.708260 CHAN A2 (12V): 0.271536 CHAN A3 (5V): 0.000576 CHAN B0 (3.3V): 0.001285 CHAN B1 (3.15aV): 0.001072 CHAN B2 (3.15bV): 0.001688 CHAN B3 (GND): 0.000147 OPEN: 0.005950 Full Scale: +/- 1 mA=#(SSBIT PASSED=#)SnListing configuration overrides from Data/persisted.cfg=#)S6CBIT.abortDepth=250 meter; =#*S6CBIT.gfScanTimeout=2 hour; =#*S4CBIT.stopDepth=200 meter; =#*S4DDM.loadAtStartup=1 bool; =#*SFDockingServo.loadAtStartup=0 bool; =#*SExpress linearApproximation CTD_Seabird.bin_median_sea_water_salinity 0.050000 practical_salinity_unit; =#*SExpress linearApproximation CTD_Seabird.bin_median_sea_water_temperature 0.500000 celsius; =#*SVLineCapture.armSpeed=1.2 meter_per_second; =#*SbLineCapture.midcourseSpeed=1.2 meter_per_second; =#+SJLineCapture.rolloutTimeout=6 minute; =#+SLLineCapture.shortFinalRange=-1 meter; =#+SJLineCapture.terminalRange=300 meter; =#+S8LineCapture.verbose=1 bool; =#+SzVerticalControl.buoyancyNeutral=152.268921 cubic_centimeter; =#+SbVerticalControl.massDefault=8.973020 millimeter; *n code=004D name="MissionManager" &T.Started mission Startup