*v 0008 ½¿ð¦”:Expecting PD13 message format=$¿Þ¼§”6Beginning ground fault scan=$¿ é§”Ground fault detected mA: CHAN A0 (Batt): 0.645855 CHAN A1 (24V): 0.712080 CHAN A2 (12V): 0.232717 CHAN A3 (5V): -0.000148 CHAN B0 (3.3V): 0.001349 CHAN B1 (3.15aV): 0.001553 CHAN B2 (3.15bV): 0.001205 CHAN B3 (GND): 0.001245 OPEN: 0.006197 Full Scale: +/- 1 mA=P¿R6”LReached waypoint: 40.333000,-70.667000*n code=00A2 name="sci2:Lap:Wpt2:A.Waypoint" =Q¿T6”XNavigating to waypoint: 40.333302,-71.166702=$¿j”6Beginning ground fault scan=$¿ê•”Ground fault detected mA: CHAN A0 (Batt): 0.627949 CHAN A1 (24V): 0.711315 CHAN A2 (12V): 0.232390 CHAN A3 (5V): -0.000338 CHAN B0 (3.3V): 0.001273 CHAN B1 (3.15aV): 0.000866 CHAN B2 (3.15bV): 0.000311 CHAN B3 (GND): -0.004129 OPEN: 0.006315 Full Scale: +/- 1 mA=¿á ”jSBD MO Status=0, MOMSN=45885, MT Status=1, MTMSN=1734=¿  ” got command stop½&¿Ü ”.Started mission Default