2021-03-23T20:15:24.066Z,1616530524.066 [CBIT](IMPORTANT): Beginning ground fault scan 2021-03-23T20:15:34.984Z,1616530534.984 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): 0.060444 CHAN A1 (24V): 0.050317 CHAN A2 (12V): 0.044581 CHAN A3 (5V): 0.017872 CHAN B0 (3.3V): 0.013727 CHAN B1 (3.15aV): 0.013497 CHAN B2 (3.15bV): 0.013185 CHAN B3 (GND): 0.000705 OPEN: 0.010452 Full Scale Calc: 4.765 mA, -1.589 mA 2021-03-23T20:25:45.786Z,1616531145.786 [transit:Transit:Wpt1.Waypoint](IMPORTANT): Reached Waypoint: 41.552299,-70.708604 2021-03-23T20:26:30.241Z,1616531190.241 [BuoyancyServo](FAULT): Overload Error 2021-03-23T20:26:32.680Z,1616531192.680 [BuoyancyServo](FAULT): LCB fault: Current Limiter Activated. 2021-03-23T20:27:09.701Z,1616531229.701 [BuoyancyServo](FAULT): Overload Error 2021-03-23T20:45:58.730Z,1616532358.730 [Default:CheckIn:E](IMPORTANT): Default mission has been running for 16.560084 min